NURSID dowels
Transmission of shear forces between two reinforced concrete components in precast construction
The NURSID dowel is a special product designed to transmit shear forces. One half of the dowel is made of round steel, while the other half is an eccentrically arranged hexagonal profile. This design compensates for installation tolerances of up to 11 mm, making the NURSID dowel ideal for connecting prefabricated balcony slabs, arcades, and similar structures.
The NURSID dowel can be combined with ESD or DB sleeves in almost any combination, allowing for both longitudinal and lateral displacements. Joint widths of up to 30 mm can be compensated for.
NURSID dowels
Benefits
- Small member thicknesses required from hmin = 150 mm
- Transmission of shear forces up to VRd = 76 kN
- Transmission of shear forces up to a joint width of 30 mm
- Systems with European Technical Assessment (ETA 23/0180)
- Comprehensive technical brochure
- Lateral movement (in the longitudinal direction of the joint) up to ±15 mm possible (cyclical lateral movements are not permitted)
- Can be combined with almost any ESD or DB sleeves
- Height difference compensation up to 11 mm
- Sleeve with integrated nailing plate
NURSID dowels
Composition

The eccentrically arranged hexagonal profile of the NURSID dowel allows for height difference compensation of up to 11 mm, depending on the dowel’s diameter, by rotating the dowel during installation.
The sleeve on the side of the hexagonal profile is designed as type “Q” (lateral movement), and the sleeve on the side of the round dowel is designed as type “N” (longitudinal movement). This means that NURSID dowel systems are always longitudinally and laterally movable.
NURSID dowels
Types
Properties of the NURSID System:
- Permissible joint widths up to 30 mm
- Height compensation of up to 11 mm
- Dowel diameters 20 – 30 mm with a yield strength of up to fyk ≥ 355 N/mm²
- Shear force transfer up to 76 kN
- Material dowel and sleeve: stainless steel
- Design tables available in the technical brochure or design software
![]() |
![]() |
Sleeve ESD-Q | Dowel NURSID | Sleeve ESD-NK |
Sleeve DB-Q | Dowel NURSID | Sleeve DB-N |
Questions? We’re here to support you.For technical or product-specific inquiries, please contact: technik@avi.at We look forward to hearing from you. |
NURSID dowels
Installation / Placement
The following sketches show the installation of NURSID dowels step by step. Depending on the selected hexagonal dowel diameter, a height compensation of up to ± 11 mm can be realised for joint widths of up to 30 mm.
Slab–Slab Connection with NURSID
NURSID dowels
Downloads
Date issue 07/24
Date issue 03/26
Continue to the download page